Rise of round-the-clock renewable power
The cost improvements in solar, wind and, more recently, battery storage systems (BESS) have been remarkable. New work from IRENA (International Renewable Energy Agency) on the economics of “24/7 renewables” adds to the discussion on how power systems can move beyond 50% renewable electricity, a threshold many EU countries have now surpassed.
The report assesses achievable F-LCOE levels (Firm Levelized Cost of Energy) for 90%, 95% and 99% firm renewable electricity from solar and onshore wind, complemented with storage, and curtailed ‘overbuild’. The report investigates favorable locations and consistently shows that the largest cost component is not the renewables production, but firming supply towards near-constant availability.
Other key findings include:
- Geography is a primary determinant of cost
- Procurement and auction design evolve towards renewable supply with BESS co-location
- Overbuild and curtailment can significantly reduce firming costs

Easy for Southern Europe. What about the north?
KYOS applied IRENA’s methodology and assumptions to a less-favorable Northwest European location. The question is how this location can deliver 90% of 1 MW baseload power using solar PV and BESS.
- With 1100 full-load hours, the solar capacity must be at least 8 MW to generate sufficient MWhs over the year. However, it would require a huge storage to spread the generation to reach the 90% firmness, by delivering summer generation in winter.
- More economical is overbuild. We found that 22 MW solar, combined with 26 MWh of 4-hour BESS can deliver 90% of 1 MW baseload.
The costs of this 22 MW solar PV and 26 MWh BESS, translate into an F-LCOE of ~180 EUR/MWh. This result is significantly higher than the ~ 79 EUR/MWh reported by IRENA for a 95% reliability system in southern Spain, Europe’s most favorable location, underscoring just how much geography matters, even within Europe.
Note that both numbers allocate all costs to the 90% delivered of 1 MW baseload, as if located on an energy island. If the PV and the BESS are, however, connected to a grid, the assets will generate additional revenues: part of the residual PV generation (around 15,000 MWh) will be delivered to the grid, while the residual BESS capacity will provide balancing services. This would improve the economics of the business case.
KYOS Takeway
The next phase of the energy transition is no longer just about deploying low-cost renewables. It is about designing and optimising electricity systems that can efficiently manage variability, flexibility and firmness, requiring increasingly advanced modelling and analytics capabilities.
Understanding the value of flexibility, firmness and portfolio effects is central to what KYOS does. If you are navigating high-renewables systems or looking to make robust investment decisions, please don’t hesitate to reach out!